TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 191 of 790

TM 5--2350--378--24&P
0012 00--4
EJECTOR DOES NOT EXTEND OR RETRACT -- Continued
0012 00
To block 5
YES
YES
NO
To block 4
NO
3
Perform mechanical binding check.
Is ejector binding?
1
Check for obstructions in bowl area.
Is ejector/bowl area free of obstructions?
2
Remove rocks or other obstructions
from bowl area
Verify problem is solved.


Back to Top