TM 5--2350--378--24&P
0011 00--10
EJECTOR CREEPS -- Continued
0011 00
Stop engine.
Verify problem with operator.
NO
YES
Does the ejector creep when loading
the bowl with earth?
9
NO
from block 1
510
11
Perform ejector relief valve test using the HDC.
Is transducer T--2 hydraulic pressure
between 1,950--2,050 psi (13,445--14,135 kPa)?
NO
YES
To block 14
To block 12