TM 5--2350--378--24&P
0020 00--4
WINCH AND RIGHT--HAND WHEEL CONTROL INOPERATIVE -- Continued
0020 00
YES
NO
1
Perform main relief valve test to verify hydraulic pressure at the 13L
main relief valve using the HDC.
Is transducer T--4 hydraulic pressure between 3,950--4,050 psi
(27,235--27,925 kPa)?
To block 4
To block 2