TM-5-3805-254-14-P-1

TRUCK, DUMP, 20 TON, 6X4, ON-OFF HIGHWAY 71,000 GVW, IHC MODEL F-5070 (CCE)

TECHNICAL MANUAL; OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT, GENERAL SUPPORT AND DEPOT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS INFORMATION AND SUPPLEMENTAL MAINTENANCE INSTRUCTIONS)

AUGUST 1980

  TM-5-3805-254-14-P-1 - Page 140 of 590

ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES
Q-QUARTERLY
S-SEMIANNUALLY
A-ANNUALLY
B-BIENNIALLY
H-HOURS
M-MILES
ITEM NO
INTERVAL
ITEM TO BE INSPECTED
Q
S
A
B
H
M
PROCEDURE: CHECK FOR AN HAVE REPAIRED, FILLED, OR ADJUSTED AS NEEDED
PERFORM ALL OPERATOR PMCS FIRST
NOTE
PERFORM OPERATOR/CREW PMCS PRIOR TO OR IN CONJUNCTION WITH ORGANIZATIONAL PMCS.
1
COOLING SYSTEM
•
a.
Check radiator for damage or obstruction.
Remove any debris which would
restrict air flow.
•
b.
Inspect hoses and lines for evidence of leaks, abrasions, kinked or
restricted areas and insecure mountings.
•
c.
Drain and flush radiator and engine.
•
d.
Check antifreeze protection (REF.TB 750-651).
•
e.
Check water pump, hoses and pipes for leaks.
2
BATTERIES
•
a.
Check for obvious defects, such as cracked case, burnt, broken or loose
battery terminals.
•
b.
Check-battery compartment for corrosion.
•
c.
Clean filler cap vent holes.
•
d.
Check specific gravity of electrolyte in each cell (REF TM 9-6140-200-14)
73


Back to Top