ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 5.
Set multimeter to 20 vdc scale.
Connect red test lead to output terminal (10) on secondary magnetic switch
(11) and black test lead to ground.
Rotate KEY SWITCH (3) clockwise to on position and check for 11 to 13
vdc on multimeter.
Rotate KEY SWITCH (3) counterclockwise to off position.
Disconnect test leads.
If multimeter does not read 11 to 13 vdc, notify Direct Support Maintenance.