BATTERY CABLES
Disconnecting
1. Perform battery box cover removal (page 2-441).
WARNING
When removing battery cables, disconnect negative (-) cable first.
Failure to observe this
precaution could cause injury to personnel or damage to equipment.
NOTE
Tag battery cables to ensure correct installation.
2. Using 3/4-inch, 1/2-inch drive socket and ratchet handle and 3/4-inch box-end wrench, unscrew and take off
negative (-)battery cable (1) from frame rail (2).
3. 1/2-inch box-end wrench, loosen and take off two positive (+) battery cable terminals (3) from batteries.
Connecting
WARNING
When installing battery cables, connect negative (-) cable last.
Failure to observe this precaution
could cause injury to personnel or damage to equipment.
NOTE
Remove tags from cables after completing installation.
4. Position two positive (+) battery cable terminals (3) on batteries and tighten using 1/2-inch box-end wrench.
5. Position negative (-) battery cable (1) on frame rail (2) and screw in and tighten using 3/4 inch, 112-inch drive
socket and ratchet handle and 3/4-inch box-end wrench.
6. Perform battery box cover installation (page 2-441).
2-444