TM-5-3805-254-20-2

TRUCK, DUMP, 20 TON, 6X4, ON-OFF HIGHWAY 71,000 GVW, IHC MODEL F-5070 (CCE)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL VOLUME 2 OF 2

JANUARY 1988

  TM-5-3805-254-20-2 - Page 357 of 971

TM 5-3805-254-20-2
WET AIR RESERVOIR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
ASSEMBLY
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
Position all elbows as shown in illustration.
25. Wet air
90-degree elbow (10)
a.
Wrap pipe threads with antiseizing tape.
reservoir (1)
b.
Screw in and tighten using 13116-inch
open-end wrench.
26.
45-degree elbow (11)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 13116-inch
open-end wrench.
27.
45-degree elbow (12)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 13/16-inch
open-end wrench.
TA244327
2-991