TM-5-3805-254-20-2

TRUCK, DUMP, 20 TON, 6X4, ON-OFF HIGHWAY 71,000 GVW, IHC MODEL F-5070 (CCE)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL VOLUME 2 OF 2

JANUARY 1988

  TM-5-3805-254-20-2 - Page 856 of 971

TM 5-3805-254-20-2
AIR CLEANER VACUUM GAGE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
6
Right instrument
Gage (4)
Take out.
panel (8)
INSPECTIONIREPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions
(page 2-424).
7
Gage (4)
a Look for cracks or dents.
b Check to see if gage is readable.
8
Mounting bracket (7)
Look for cracks, bends, or breaks.
9
All threaded parts
Look for damaged threads or rounded
heads.
TA244631
2-1467


Back to Top