WATER TEMPERATURE GAGE AND LINE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
16 Gage (1)
Mounting bracket (2)
Put on.
17
Two nuts (3)
Screw on and tighten using 3/8-inch open-
and two new
end wrench.
lockwashers (4)
18
Light socket (5)
Push in.
NOTE
FOLLOW-ON MAINTENANCE:
1 Close center instrument panel (page 2-424).
2 Fill cooling system (page 2-628).
3 Close left side cab door (page 2-424).
4 Close right and left side hood panels (page 2-424).
TASK ENDS HERE