TM 5-3805-254-20-2
AIR CLEANER VACUUM GAGE LINE AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
7
Straight pipe
Line (2)
Using 9/16-inch and 7/16-inch open-end
fitting (1)
wrenches, unscrew and take off.
8
Coupling (3)
Straight pipe
Using 7/16-inch and 1/2-inch open-end
fitting (1)
wrenches, unscrew and take out.
9
Air cleaner
Coupling (3)
Using 1/2-inch open-end wrench, unscrew
housing (4)
and take off.
CLEANING
WARNING
Improper cleaning methods and use of unauthorized cleaning liquids or solvents can injure personnel and
cause damage to equipment Refer to TM 9-247.
NOTE
Line and fittings must be cleaned thoroughly.
TA244644
2-1484