TM-5-3805-274-13-P

DUMP TRUCK BODY M917

TECHNICAL MANUAL; OPERATOR AND FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

AUGUST 2013

  TM-5-3805-274-13-P - Page 78 of 364

TROUBLESHOOTING PROCEDURES
SYMPTOM
Dump bed rattles and side or front panels give under load.
MALFUNCTION
Inspect for broken weld seams.
Inspect for misaligned or damaged tailgate.
Inspect for severely dented front or side panels and reinforcement braces.
CORRECTIVE ACTION
1. Repair any broken welds, notify your supervisor.
2. Repair or replace tailgate. Refer to WP 0030.
3. Straighten as necessary and repair any damaged welds, notify your supervisor.
END OF TASK
SYMPTOM
Mud flap(s) are missing or not hanging straight.
MALFUNCTION
Inspect for loose or missing mounting hardware.
Inspect for damaged mud flap(s).
CORRECTIVE ACTION
1. Install mud flap(s) and hardware as required. Refer to WP 0027.
2. Replace mud flap(s). Refer to WP 0027.
END OF TASK
SYMPTOM
Cab protector rattles.
MALFUNCTION
Inspect for broken weld seams at bracing.
Inspect for damage causing misalignment of bottom plate.
CORRECTIVE ACTION
1. Repair any broken welds, notify your supervisor.
2. Straighten bracing and repair any broken welds, notify your supervisor.
END OF TASK
SYMPTOM
Tailgate does not open or close completely and binds during operation.
MALFUNCTION
Inspect for bent hinge pins.
Inspect for misalignment caused by broken welds and/or bent reinforcement braces.
CORRECTIVE ACTION
1. Straighten or replace hinge pins. Refer to WP 0030.
2. Straighten and repair welds as required, notify your supervisor.
END OF TASK
TM 5-3805-274-13&P
0016
0016-2