TM 5-3895-372-20
Section II TROUBLESHOOTING
13-5.
INTRODUCTION.
No special troubleshooting procedures are required for the lighting system of the mixer body.
If the lamps malfunction,
use the general procedures below.
13-6.
GENERAL PROCEDURES.
a.
If all of the mixer body lamps fail to function, the problem may be in the chassis electrical system.
Check
whether the chassis marker and clearance lamps are functioning.
If they are not, refer to TM 9-2320-273-20 for
troubleshooting procedures.
If they are, check that the mixer body lamps are securely plugged in.
b.
All other malfunctions in the mixer body lighting system may be traced to one of the following causes:
(1)
Burnt-out bulbs.
(2)
Loose connections.
(3
) Frayed, broken, or corroded wires.
Replace bulbs, tighten connections, and repair wiring, as necessary.
Section III MAINTENANCE PROCEDURES
13-7.
INTRODUCTION.
This section provides you with Organizational Level maintenance procedures for the lamps and wiring system of the mixer
body.
Paragraph 13-8 summarizes the maintenance tasks.
Paragraphs 13-9 thru 13 11 contain detailed instructions for
each task.
13-2