TM-5-3990-263-13-P

PALLET, ADAPTER, BRIDGE, M15

TECHNICAL MANUAL; OPERATOR AND FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST (RPSTL)

APRIL 2012

  TM-5-3990-263-13-P - Page 269 of 728

FIELD MAINTENANCE
FRONT PIN LOCK WILL NOT OPERATE
INITIAL SETUP:
Tools and Special Tools
Tool Kit, General Mechanic's: Automotive
(WP
0078, Table 2, Item 1)
Materials/Parts
Lockwasher (WP
0082, Table 1, Item 41) Qty:
6
Lockwasher (WP
0082, Table 1, Item 43) Qty:
2
References
WP
0052
WP
0063
WP
0064
Equipment Condition
Engine turned off. (TM 9-2320-435-10 or TM
9-2320-425-10) (WP
0076)
Equipment Condition (cont.)
Parking brakes applied. (TM 9-2320-435-10 or
TM 9-2320-425-10) (WP
0076)
Wheels chocked. (TM 9-2320-435-10 or
TM 9-2320-425-10) (WP
0076)
Load removed from the BAP. (WP
0006)
CBT air supply fully charged. (TM 9-2320-435-10
or TM 9-2320-425-10) (WP
0076)
BAP air supply hose connected to HEMITT supply
air coupling. (WP
0011)
TROUBLESHOOTING PROCEDURE
SYMPTOM
Front Pin Lock will not Operate.
MALFUNCTION
Vehicle Air Supply is Faulty.
CORRECTIVE ACTION
WARNING
Air system is under pressure. Never point airflow toward personnel. Failure to
comply may result in serious injury or death to personnel.
NOTE
Front pin locks will not operate without sufficient air pressure.
1.
Loosen hose clamp (Figure 1).
TM 5-3990-263-13&P
0030
0030-1


Back to Top