TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 1025 of 1188

TM 5-4210-249-13&P-1
0118-9
DRAFT
0118
TFFT03434
Step 8.
Connect valve control wire harness connector to tank fill & re-circulating line valve
motor.
Disconnect valve control wire harness connectors from DRIVER MAIN INLET
valve control.
Connect tank fill & re-circulating line valve control wire harness connector
to DRIVER MAIN INLET valve control.
Turn battery disconnect switch to ON
position (WP 0007).
While an assistant pushes pump operator’s panel DRIVER MAIN
INLET valve control OPEN and CLOSE buttons (WP 0004), check if tank fill & re-
circulating line valve operates.
a.
If tank fill & re-circulating line valve operates, reconnect valve control
wire harness connectors to original positions and replace TANK FILL &
RE-CIRCULATING LINE valve control (WP 0418).
b.
If tank fill & re-circulating line valve does not operate, reconnect valve
control wire harness connectors to original positions and replace tank
fill & re-circulating line valve motor (WP 0388).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top