TM 5-4210-249-13&P-1
0118-12
DRAFT
0118
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
TFFT03437
Step 12.
Disconnect pump operator’s panel wire harness pump house power distribution wire
harness connector DP2.
With a test lead set, check for 22 to 28 VDC between pump
house power distribution wire harness wire 4083 (green) at connector DP2, terminal N
and a known good ground.
a.
If 22 to 28 VDC are present, repair wire 4083 in pump operator’s panel
wire harness if repairable
(TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0459).
b.
If 22 to 28 VDC are not present, repair wire 4083 in pump house power
distribution wire harness if repairable (TM 9-2320-325-14&P), or
replace pump house power distribution wire harness and
block (WP 0457).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top