TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 103 of 1188

TM 5-4210-249-13&P-1
0004-33/(34 blank)
DRAFT
0004
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
END OF WORK PACKAGE
TFFT00943P
Figure 26. Hydraulic Generator Display.
Key
Fig. 26
Control or Indicator
Function
1
FREQUENCY LED Display
Displays generator output frequency in Hz. Range: 0 to 99.9 Hz in
one-tenth Hz increments.
2
AMPS LINE 1 and AMPS LINE 2
LED Display
Displays amperage for each of two generator output lines.
Range:
0 to 150 in one-ampere increments.
3
AC VOLTS LED Display
Displays generator output voltage.
Range: 0 to 300 VAC in one-
volt increments.
4
MODE Button
Allows user to switch sequentially through STANDARD display
mode, OPERATIONAL HOURS display mode and ENGINE OIL
TEMPERATURE display mode.
5
OPERATIONAL HOURS Display
Mode
Displays “HR” in the “FREQUENCY” LED panel and total
generator operating hours in the “AMPS LINE 1” and “AMPS LINE
2” LED panels.
Range: 0 to 99999.9 hours in one-tenth hour
increments.
6
ENGINE OIL TEMPERATURE
Display Mode
Displays “OIL” in the “FREQUENCY” LED panel and engine oil
temperature in the “AMPS LINE 1” LED panel.
The “AMPS LINE
2”
LED panel displays “ºF.” Range: 0 to 230ºF in one-degree
increments.
7
POWER ON Light
Illuminates when generator is engaged.
8
Fuses
Protect against circuit overload by interrupting current flow if draw
is above the circuit limit.


Back to Top