TM 5-4210-249-13&P-1
0004-27
DRAFT
0004
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00424P
Figure 19. Passenger Side of Pump House.
Key
Fig. 19
Control or Indicator
Function
1
PASSENGER SIDE AUX. INLET
Used to pump water from hydrant or from a positive water source.
2
NO. 3 PASSENGER SIDE
DISCHARGE Drain Valve
Opens and closes discharge drain valve for the No. 3
PASSENGER SIDE DISCHARGE plumbing.
3
NO. 4 PASSENGER SIDE
DISCHARGE Drain Valve
Opens and closes discharge drain valve for the No. 4
PASSENGER SIDE DISCHARGE plumbing.
4
DRIVER PRE-CONNECT B
Drain Valve
Opens and closes discharge drain valve for the DRIVER
PRE-CONNECT B discharge plumbing.
5
120 VAC, 15 AMP, 60 Hz
Receptacle
Provides power for lights and other accessories.
6
NO. 3 PASSENGER SIDE
DISCHARGE
Discharge connection for use with 3 in. (7.6 cm) hoses.
7
NO. 4 PASSENGER SIDE
DISCHARGE
Discharge connection for use with 3 in. (7.6 cm) hoses.
8
MASTER DRAIN Valve
Opens and closes master drain valve.
9
A FOAM TANK DRAIN Valve
Used to drain foam agent from foam tank A.
10
B FOAM TANK DRAIN Valve
Used to drain foam agent from foam tank B.