TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 1117 of 1188

TM 5-4210-249-13&P-1
0124-3/(4 blank)
DRAFT
0124
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Perform post operations procedures (WP 0041)
2.
Remove Blow-out Adapter (if installed) (WP 0044)
3.
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
TFFT03975
Step 3.
Stop water pump engine (WP 0022).
Install discharge and intake caps on
vehicle (WP 0004).
Install blow-out adapter on PASSENGER SIDE AUX.
INLET (WP 0044).
Apply 50 psi (345 kPa) shop air to PASSENGER SIDE AUX. INLET.
Push PASSENGER SIDE AUX. INLET button to OPEN position (WP 0004).
Push NO.
1 DRIVER SIDE DISCHARGE PRESSURE button (WP 0004).
Check if pressure
indicated at NO. 1 DRIVER SIDE DISCHARGE is equal to value indicated at pump
operator’s panel PUMP DISCHARGE gauge.
a.
If NO. 1 DRIVER SIDE DISCHARGE value is equal to PUMP
DISCHARGE gauge, replace water pump (WP 0255).
b.
If NO. 1 DRIVER SIDE DISCHARGE value is not equal to PUMP
DISCHARGE gauge, troubleshoot Digital Pressure Gauge(s) Does Not
Operate (WP 0127).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top