TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 1121 of 1188

TM 5-4210-249-13&P-1
0125-3
DRAFT
0125
TFFT2729
NOTE
Water will be expelled at windshield when operating windshield deluge system.
Move
vehicle to outside area or place suitable container under windshield.
Windshield deluge pump motor operation will be checked by listening for a whining sound
from windshield deluge pump when WINDSHIELD DELUGE switch is put to on position.
Step 2.
Open pump house panel A (WP 0539).
Put WINDSHIELD DELUGE switch to on
position (WP 0004).
Check if windshield deluge pump operates.
If windshield deluge pump does not operate, go to Step 11.
Step 3.
Check if water is delivered from at least one windshield deluge nozzle, when windshield
deluge system is operating.
If water is not delivered to both windshield deluge nozzles, go to Step 5.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top