TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 139 of 1188

TM 5-4210-249-13&P-1
0020-1
DRAFT
0020
OPERATOR MAINTENANCE
WATER TANK FILL
NOTE
The TFFT can be filled four different ways.
MAIN INLET
NOTE
•
Valve is completely closed when red indicator light illuminates.
•
Main Inlet may be operated with either 5 in. (13 cm) or 3 in. (7.6 cm) soft suction hose.
•
5 in. (13 cm) and 3 in. (7.6 cm) suction hoses operate the same way.
5 in. (13 cm) suction
hose shown.
1.
Push DRIVER MAIN INLET valve control CLOSE button (1) until red indicator light (2) illuminates.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
-
-
-
-
TFFT02191


Back to Top