TM 5-4210-249-13&P-1
0020-5
DRAFT
0020
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Valve is completely closed when red indicator light illuminates.
10. Push TANK FILL & RE-CIRCULATING LINE valve control CLOSE button (12) until red indicator light (13)
illuminates.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Valve is completely closed when red indicator light illuminates.
11. Push DRIVER SIDE MAIN INLET valve control CLOSE button (14) until red indicator light (15) illuminates.
12. Close supply valve on positive water source.
TFFT02197