0026-3
DRAFT
0026
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
All discharges and pre-connects are operated the same way.
NO. 1 DRIVER SIDE
DISCHARGE shown.
7.
Remove cap (5) from NO. 1 DRIVER SIDE DISCHARGE (6).
8.
Connect discharge hose (7) to NO. 1 DRIVER SIDE DISCHARGE (6).
9.
Set pressure governor (WP 0024).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
10. Push NO.1 DRIVER SIDE DISCHARGE valve control OPEN button (8) until desired pressure is achieved.
Green indicator light (9) will illuminate.
11. Open other discharge valves to desired setting.
NOTE
Perform Steps (12) through (16) if performing direct tank fill.
12. Connect hose from positive water source to direct tank fill inlets as required.
13. Open supply valve on positive water source.