TM 5-4210-249-13&P-1
0042-1
DRAFT
0042
OPERATOR MAINTENANCE
WATER PUMP AND WATER TANK FLUSH
WATER PUMP FLUSH
NOTE
•
Valve is completely closed when red indicator light illuminates.
•
Main inlet may be operated with either a 5 in. (13 cm) or 3 in. (7.6 cm) suction hose.
•
5 in. (13 cm) and 3 in. (7.6 cm) suction hoses operate the same way.
1.
Push DRIVER MAIN INLET valve control CLOSE button (1) until red indicator light (2) illuminates.
2.
Remove cap (3) from driver main inlet (4).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Do not use hard suction hose for Step (3).
Hard suction hose will not hold pressure.
Hose may fail and separate causing injury to personnel and damage to equipment.
3.
Connect 5 in. (13 cm) or 3 in. (7.6 cm) soft suction hose to driver main inlet (4) and positive water source.
TFFT02208
TFFT02209
WARNING
ICON 72