TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 235 of 1188

TM 5-4210-249-13&P-1
0042-3
DRAFT
0042
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Do not let pressure exceed 125 psi (862 kPa).
Failure to comply may result in injury
or death to personnel or damage to equipment.
NOTE
If pressure exceeds 125 psi (862 kPa) notify Supervisor.
7.
Start water pump engine (WP 0022).
8.
Open supply valve on positive water source.
9.
Prime water pump (WP 0023).
10. Set pressure governor (WP 0024).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CAUTION
Cavitation can occur when pumping and air enters water.
If engine speed increases
without an increase in pressure, pump may be cavitating.
Even though pump may
be primed, air leaks can cause rough operation and an increase in engine speed
without an increase in pressure or flow.
If an air leak is suspected, discontinue
pumping and isolate problem.
Cavitation can also occur with large nozzle tips.
Solve this problem by reducing flow.
Failure to comply may result in damage to
water pump.
11. Remove cap (8) from NO. 1 DRIVER SIDE DISCHARGE (9).
WARNING
ICON 72
TFFT2212


Back to Top