TM 5-4210-249-13&P-1
0094-1
DRAFT
0094
FIELD LEVEL MAINTENANCE
FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL
METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF
INITIAL SETUP:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL
METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF
NOTE
•
Ensure system air pressure is at least 85 psi (586 kPa) during this procedure.
System air
pressure is required to activate valves.
•
Do not engage water pump engine during this procedure, except when performing
complete system checks.
Valve operations can be checked without water pump
operation.
•
Valve operations can be checked by observing valve shaft rotation.
Valves are open when
tabs or yellow paint tabs are aligned with direction of fluid flow.
Tools and Special Tools
Drain Pan (WP 0622, Item 9)
Lead Set, Test (WP 0622, Item 21)
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Personnel Required
MOS 63B Wheeled vehicle mechanic (2)
References
TM 9-2320-325-14&P
WP 0004
WP 0007
WP 0019
WP 0287
WP 0290
WP 0311
WP 0315
WP 0325
WP 0330
References (continued)
WP 0401
WP 0402
WP 0426
WP 0427
WP 0441
WP 0443
WP 0455
WP 0459
WP 0499
WP 0463
WP 0539
WP 0540
WP 0550
WP 0567
Equipment Conditions
Water pump engine OFF (WP 0022)
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)