TM 5-4210-249-13&P-1
0094-3
DRAFT
0094
TFFT03704
Step 4.
While an assistant puts personnel cab FOAM SYSTEM switch to on position
(WP 0004), check if eductor valve operates to open position.
If eductor valve does not operate to open position, go to Step 8.
Step 5.
While an assistant puts personnel cab FOAM SYSTEM switch to off position
(WP 0004), check if eductor valve operates to closed position.
If eductor valve does not operate to closed position, go to Step 7.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION