TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 642 of 1188

TM 5-4210-249-13&P-1
0098-12
DRAFT
0098
TFFT03495
Step 13.
Remove pump house panel S (WP 0540).
Put cab FOAM SYSTEM switch to off
position (WP 0004).
Push and release roof turret agent discharge button (WP 0004).
Check air lines from FOAM A shutoff valve control manifold to foam system flow control
manifold for leaks, kinks, or damage.
If air lines are not free from leaks, kinks, or damage, replace damaged air
lines (WP 0567).
Step 14.
Check lines from ROOF TURRET FOAM A foam system flow control manifold to roof
turret foam A multi-metering valve cylinder for leaks, kinks, or damage.
If air lines are not free from leaks, kinks, or damage, replace damaged air
lines (WP 0567).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top