Step 16.
Put cab FOAM SYSTEM switch to off position (WP 0004).
Reconnect air line at roof
turret foam A multi-metering valve cylinder.
Disconnect valve control wire harness roof
turret foam A multi-metering connector.
Put cab FOAM SYSTEM switch to on position
(WP 0004).
Put cab FOAM SELECT switch to A position (WP 0004).
With a test lead
set, check for 22 to 28 VDC between valve control wire harness wire 4055 (purple) at
ROOF TURRET FOAM A foam system flow control manifold connector, terminal 1, and
a known good ground.
If 22
to 28 VDC are not present, repair wire 4055 (purple) in valve control
wire harness if repairable (TM 9-2320-325-14&P), or replace valve control
wire harness (WP 0463).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION