TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 673 of 1188

TM 5-4210-249-13&P-1
0101-5
DRAFT
0101
TFFT03999
Step 5.
Put pump operator’s panel FOAM FLUSH switch to OFF position (WP 0004).
While an
assistant puts pump operator’s panel FOAM SYSTEM switch to ON
position (WP 0004), check if eductor valve operates to open position.
a.
If eductor valve operates to open position, replace foam flush shutoff
control diode pack (WP 0426).
b.
If eductor valve does not operate to open position, troubleshoot Foam
Not Delivered From All Systems (Bumper Turret, Ground Sweeps, and
Manual Metering Controls) or System Does Not Shut Off (WP 0094).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top