TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 799 of 1188

TM 5-4210-249-13&P-1
0106-9
DRAFT
0106
TFFT03421
Step 11.
Connect valve control wire harness connector to driver main inlet valve motor.
Disconnect valve control wire harness connector from TANK FILL & RE-CIRCULATING
valve control.
Connect driver main inlet valve control wire harness connector to TANK
FILL & RE-CIRCULATING valve control.
While an assistant pushes pump operator’s
panel TANK FILL & RE-CIRCULATING valve control OPEN and CLOSE buttons
(WP 0004), check if driver main inlet valve operates.
a.
If driver main inlet valve operates, reconnect valve control wire
harnesses to original positions and replace DRIVER MAIN INLET valve
control (WP 0418).
b.
If driver main inlet valve does not operate, reconnect valve control wire
harnesses to original positions and replace driver main inlet valve
motor (WP 0388).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top