Step 13.
Install circuit breaker P15 (WP 0412).
Open pump operator’s panel housing
(WP 0325).
Disconnect pump operator’s panel wire harness DRIVER MAIN INLET
valve control connector.
Turn battery disconnect switch to ON position (WP 0007).
Check for 22 to 28 VDC between pump operator’s panel wire harness wire 4082 (gray)
at DRIVER MAIN INLET valve control connector, terminal A and a known good ground.
If 22 to 28 VDC are not present, go to Step 15.
Step 14.
Turn battery disconnect switch to OFF position (WP 0007).
With a test lead set, check
for continuity across wire 3895 (black) from pump operator’s panel wire harness
DRIVER MAIN INLET valve control connector, terminal B and a known good ground.
a.
If there is continuity, replace DRIVER MAIN INLET valve control
(WP 0418).
b.
If there is no continuity, repair wire 3895 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0459).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION