TM 5-4210-249-13&P-1
0109-6
DRAFT
0109
TFFT02692
Step 9.
Open pump operator’s panel housing (WP 0325).
Check discharge valve control wire
harness at NO. 1 DRIVER SIDE DISCHARGE valve control and No. 1 driver side
discharge valve motor for loose connections.
If discharge valve control wire harness connectors are loose, reconnect
loose connectors (WP 0453).
NOTE
•
Engine may have to be running to provide enough power to operate valve control.
Valve
will operate with less voltage, but only yellow indicator light will register on valve control.
•
Do not engage water pump engine during this procedure.
Valve operations can be
checked without water pump operation.
•
Valve motor operation can be checked by noting vibration of valve assembly, or by
observing rotation of 7/16 in. hex at end of valve drive assembly worm gearshaft.
•
Do not remove cap from No. 1 driver side discharge.
Water may be released from system
when valve is operated.
Step 10.
While an assistant pushes pump operator’s panel NO. 1 DRIVER SIDE DISCHARGE
valve control OPEN and CLOSE buttons (WP 0004), check if NO. 1 DRIVER SIDE
DISCHARGE valve control yellow indicator light illuminates and No. 1 driver side
discharge valve motor operates.
If yellow indicator light illuminates and valve motor operates, replace No. 1
driver side discharge valve drive assembly (WP 0388).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION