TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 855 of 1188

TM 5-4210-249-13&P-1
0110-3
DRAFT
0110
TFFT02643
NOTE
Valve operation can be checked by noting vibration of valve assembly or by observing
rotation of 7/16 in. hex at end of valve drive assembly worm gearshaft.
Do not remove cap from NO. 2 DRIVER SIDE DISCHARGE.
Water may be released from
system when valve is operated.
Step 2.
Open pump house panel A (WP 0539). While an assistant pushes pump operator’s
panel NO. 2 DRIVER SIDE DISCHARGE valve control OPEN and CLOSE buttons
(WP 0004), check if No. 2 driver side discharge valve operates to open and close
positions.
If No. 2 driver side discharge valve does not open and close, go to Step 9.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top