TM 5-4210-249-13&P-1
0111-3
DRAFT
0111
TFFT02658
NOTE
Valve operation can be checked by noting vibration of valve assembly or by observing
rotation of 7/16 in. hex at end of valve drive assembly worm gearshaft.
Do not remove cap from NO. 3 PASSENGER SIDE DISCHARGE.
Water may be
released from system when valve is operated.
Step 2.
Remove pump house panel G (WP 0540).
While an assistant pushes pump operator’s
panel NO. 3 PASSENGER SIDE DISCHARGE valve control OPEN and CLOSE
buttons (WP 0004), check if No. 3 passenger side discharge valve operates to open
and close positions.
If No. 3 passenger side discharge valve does not open and close, go to
Step 9.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION