TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 956 of 1188

TM 5-4210-249-13&P-1
0115-10
DRAFT
0115
TFFT04110
Step 13.
Turn battery disconnect switch to OFF position (WP 0007).
Remove driver main inlet
primer valve inline fuse (WP 0261).
Turn battery disconnect switch to ON position
(WP 0007).
While an assistant pushes and holds pump operator’s panel DRIVER
MAIN INLET PRIMER switch (WP 0004), check for 22 to 28 VDC between pump house
wire harness driver main inlet primer valve inline fuse connector, terminal wire 4066
(orange) and a known good ground.
If 22 to 28 VDC are not present, replace driver main inlet primer valve
control solenoid (WP 0266).
Step 14.
Check for continuity across driver main inlet primer valve inline fuse from terminal to
terminal.
a.
If continuity is present, repair wire 4067 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0458).
b.
If continuity is not present, replace driver main inlet primer valve inline
fuse (WP 0261).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION