TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 963 of 1188

TM 5-4210-249-13&P-1
0115-17
DRAFT
0115
TFFT04173
Step 27.
Press pump operator’s panel PUMP PRIMER switch (WP 0004).
Check for primer
pump operation.
If primer pump does not operate when pump operator’s panel PUMP
PRIMER switch is pressed, go to Step 43.
Step 28.
Push pump operator’s panel PUMP PRIMER switch (WP 0004).
Check if primer pump
draws water to water pump (WP 0025).
If primer pump operates but does not draw water to water pump, go to
Step 30.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top