INSTALLATION
1.
Install drain hose (44) on air conditioner/heater assembly (5).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
2.
Apply adhesive to drain hose (44).
3.
Install drain hose (43), elbow (42), clamp (41), drain hose (40), and clamp (39) on air conditioner/heater
assembly (5).