TM 5-4210-249-13&P-2
0218-4
DRAFT
0218
INSTALLATION
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
1.
Install sealing compound to threads of plug (21), five plugs (20), three plugs (19), drain cock (18), two
elbows (4), and fitting (2).
NOTE
Install plugs, elbows, and fittings as noted prior to removal.
2.
Install plug (21) on air reservoir (9).
3.
Install five plugs (20) on air reservoir (9).
4.
Install three plugs (19) on air reservoir (9).
5.
Install drain cock (18) on air reservoir (9).
6.
Install two elbows (4) on air reservoir (9).
7.
Install fitting (2) on air reservoir (9).
TFFT00101
WARNING