TM 5-4210-249-13&P-2
0267-1
DRAFT
0267
FIELD LEVEL MAINTENANCE
PUMP PRIMER VALVE REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Tag and mark wires and hoses prior to removal to ensure proper installation.
1.
Remove nut (1) and wire (2) from stud (3).
2.
Straighten cable wire (4).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00268
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Adhesive, RTV 732 (WP 0625, Item 2)
Compound, Sealing, Pipe Thread
(WP 0625, Item 21)
Tags, Identification (WP 0625, Item 51)
Lockwasher (2)
Locknut (2)
Locknut (2)
Locknut (4)
References
WP 0615, Fig. 41
Equipment Conditions
Water system drained (WP 0041)
Pump house panel A opened (WP 0539)