TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 1308 of 1452

TM 5-4210-249-13&P-2
0268-4
DRAFT
0268
INSTALLATION
1.
Install bracket (13) on pipe (34) with two U-bolts (33), cradles (32), and four locknuts (31).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Use sealing compound sparingly only on pipe threads.
Do not apply compound to
hose connections.
Damage to equipment may result.
2.
Apply sealing compound to threads of fitting (30) and two elbows (18) and (20).
3.
Install fitting (30) on primer valve (24).
4.
Install elbow (20) on fitting (30).
5.
Install elbow (18) on primer valve (24).
6.
Install primer valve (24) on bracket (13) with U-bolt (23), cradle (22), and two locknuts (21).
Do not tighten
locknuts.
7.
Install U-bolt (29), two cables (27) and (26), primer valve (24), and cradle (28), on bracket (13) with two
locknuts (25).
8.
Tighten two locknuts (21).
TFFT01992A
WARNING
ICON 30, 44, 27


Back to Top