TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 1309 of 1452

TM 5-4210-249-13&P-2
0268-5
DRAFT
0268
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
9.
Apply electrical sealant on ends of two cables (26) and (27).
10. Install line (19) on elbow (20).
11. Install line (17) on elbow (18).
12. Position pin (14) and four washers (15) on arm (16).
13. Position cable wire (4) through pin (14).
NOTE
Install cable as noted prior to removal.
Ensure manual primer handle is in closed position (pushed down) and primer valve lever
is forward prior to installing cable bracket.
14. Install cable (12) on bracket (13) with two cushion clips (11), screws (10), four washers (9), two
lockwashers (8), and nuts (7).
15. Install retainer (6) on cable wire (4) and tighten screw (5).
NOTE
Cable wire must be bent a minimum of 90 degrees.
Failure to comply may allow retainer
to come loose and not allow primer cable to function.
16. Bend cable wire (4).
WARNING
ICON 30, 44, 27
TFFT01992C


Back to Top