TM 5-4210-249-13&P-2
0281-1
DRAFT
0281
FIELD LEVEL MAINTENANCE
FOAM LEVEL PROBE REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
•
Both foam probes are removed the same way.
•
Remove cable ties as required.
•
Perform Step (1) to remove foam level probe cover.
1.
Remove four screws (1), washers (2), and cover (3) from hose bed (4).
2.
Remove heat shrink (5) and disconnect connector (6).
3.
Remove four screws (7), foam level probe (8), and gasket (9) from tank (10).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT01082
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Shrink, Heat (WP 0625, Item 48)
Ties, Cable, Plastic (WP 0625, Item 58)
References
WP 0191
WP 0615, Fig. 51, 136
Equipment Conditions
Water pump engine OFF (WP 0022)
Batteries disconnected (TM 9-2320-325-14&P)