TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 192 of 1452

TM 5-4210-249-13&P-2
0136-2
DRAFT
0136
TFFT02569
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 2.
Turn battery disconnect switch to OFF position (WP 0007).
Remove lamp from pump
operator’s panel PUMP COOLER indicator (WP 0327).
Check for continuity across
lamp.
If there is no continuity, replace lamp (WP 0327).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top