Step 6.
Remove crew cab driver side access panel (WP 0499).
Remove pump house panel Q
(WP 0540).
Disconnect main wire harness pump operator’s panel wire harness
connector DO1.
With a test lead set, check for continuity across pump operator’s panel
wire harness wire 4075 (red) from pump operator’s panel PUMP ENGINE RUNNING
indicator to pump operator’s panel wire harness connector DO1, terminal S.
a.
If continuity is present, replace pump operator’s panel PUMP ENGINE
RUNNING indicator (WP 0326).
b.
If continuity is not present, repair wire 4075 in pump operator’s panel
wire harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0459).
Step 7.
Check if pump operator’s panel PUMP ENGINE RUNNING indicator
illuminates (WP 0004).
If pump operator’s panel PUMP ENGINE RUNNING indicator does not
illuminate, go to Step 12.