TFFT03689
Step 2.
Release PUMP PRIME switch (WP 0004).
While pressing pump operator’s panel
PUMP HOT PUSH TO TEST button, check if PUMP HOT audio alarm
sounds (WP 0004).
If PUMP HOT audio alarm does not sound, go to Step 10.
Step 3.
While pressing pump operator’s panel PUMP HOT PUSH TO TEST button, check if
PUMP HOT indicator illuminates (WP 0004).
If PUMP HOT indicator does not illuminate, go to Step 8.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION