TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 232 of 1452

TM 5-4210-249-13&P-2
0141-2
DRAFT
0141
TFFT03560
Step 1.
Remove pump house panel S (WP 0540).
Disconnect valve control wire harness water
tank drain control valve connector. Turn battery disconnect switch to ON
position (WP 0007).
Put pump operator’s panel WATER TANK DRAIN switch to OPEN
position (WP 0004).
With a test lead set, check for 22 to 28 VDC between valve control
wire harness wire 4053 (brown) at water tank drain control valve connector, terminal 1
and a known good ground.
If 22 to 28 VDC are not present, troubleshoot Water Tank Drain Valve Does
Not Operate When Selected (WP 0122).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top