TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 243 of 1452

TM 5-4210-249-13&P-2
0143-3
DRAFT
0143
TFFT03746
Step 3.
Install lamp in pump operator’s panel TANK TO PUMP indicator (WP 0327).
Open
pump operator’s panel housing (WP 0325).
Check for continuity across pump
operator’s panel wire harness wire 3895 (black) from pump operator’s panel TANK TO
PUMP indicator to a known good ground.
If there is no continuity, repair wire 3895 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator’s
panel wire harness (WP 0459).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top