TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 244 of 1452

TM 5-4210-249-13&P-2
0143-4
DRAFT
0143
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
TFFT03747
Step 4.
Turn battery disconnect switch to ON position (WP 0007).
Put pump operator’s panel
TANK TO PUMP switch to OPEN position (WP 0004).
Check for 22 to 28 VDC between
pump operator’s panel wire harness wire 2855 (red) from pump operator’s panel TANK
TO PUMP indicator to a known good ground.
a.
If 22 to 28 VDC are present, replace TANK TO PUMP
indicator (WP 0326).
b.
If 22 to 28 VDC are not present, repair wire 2855 in pump operator’s
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator’s panel wire harness (WP 0459).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top