TM 5-4210-249-13&P-2
0127-10
DRAFT
0127
TFFT04358
Step 19.
Turn battery disconnect switch to OFF position (WP 0007).
Reconnect pump intake
digital gauge pressure transducer wire harness connector to PUMP INTAKE
gauge (WP 0317).
Disconnect pump discharge pressure transducer from pump
discharge transducer wire harness connector.
With a test lead set, check for continuity
across sensor signal wire from pump discharge pressure transducer wire harness
connector, terminal 2, to pump discharge pressure transducer wire harness connector,
terminal C.
If continuity is not present, repair sensor ground wire in pump intake
pressure transducer wire harness if repairable (TM 9-2320-325-14&P), or
replace pressure transducer wire harness (WP 0460).
Step 20.
With a test lead set, check for continuity across sensor ground wire from pump
discharge pressure transducer wire harness connector, terminal 6, to pump discharge
transducer wire harness connector, terminal A.
If continuity is not present, repair sensor ground wire in pump intake
pressure transducer wire harness if repairable (TM 9-2320-325-14&P), or
replace pressure transducer wire harness (WP 0460).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION