TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 52 of 1452

TM 5-4210-249-13&P-2
0127-16
DRAFT
0127
TFFT04331
Step 31.
Open pump operator’s panel (WP 0325).
Check pump discharge pressure line from
pump discharge pressure test gauge panel to primer pump connector at water pump
output for leaks, kinks, or damage (WP 0490).
a.
If pump discharge pressure line is not free from leaks, kinks, or
damage, replace pump intake pressure line (WP 0490).
b.
If pump discharge pressure line is free from leaks, kinks, or damage,
replace pump discharge pressure transducer (WP 0411).
TFFT04539
Step 32.
Check if personnel cab PUMP DISCHARGE digital pressure gauge illuminates.
If personnel cab PUMP DISCHARGE digital pressure gauge does not
illuminate, go to Step 35.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION